| Sign In | Join Free | My entremaqueros.com |
|
Brand Name : YJJ
Model Number : 1O2 AAW85-07WA-CIT
Place of Origin : Britain
MOQ : 1
Price : Negotiable
Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability : 1500
Delivery Time : 5-8 days
Packaging Details : Pouching
Working principle : Lead-free electrochemical principle
Power supply voltage : 3 - 3.6V DC
Power consumption : 0.48mW
Operating current : 146.79μA
Measurement range : 0% - 25% vol O2
Resolution : 0.1% O2
Product Description:
YJJ 1O2 AAW85-07WA-CIT Electrochemical Oxygen O2 Gas Sensor Is Used For Industrial Safety
Features:
Oxygen (O2) simulates a gas sensor
Main features and advantages
Commissioning of small instruments
Designed to meet global performance standards.
The ANSI/ISA 92.04.01:2007
BS EN 50104:2010
AS/NZS 4641-2007
Improve performance across extended environments
Five years of expected operating life
Conforms to RoHS and lead free electrochemical design
Technical specifications
measurement
Lead free electrochemical technology
Measurement range 0.6%vol.O2 to 25%vol.O2.
Max overload 30%vol.O2
Airborne filter None
Sensitivity * 80 mA to 130 mA (in air).
T50 Response time *
< 10 seconds (at 20°C)
< 15 seconds (at -40°C to +60°C)
T90 response time * normal < 15 seconds
R90 Recovery time *< 45 seconds (@20°C to +60°C).
R95 Recovery time; 60 seconds
Zero current (offset)(N2 after 3 minutes)
< 0.6% vol.O2 equivalent normally < 0.3% vol.O2 equivalent
For the preheating time, see the feature description
Repetition. ±5% of the measured value.
Linear S=K loge 1/(1-c)
Specifications:
| Measurement Range | 0.6% vol. O2 to 25% vol. O2 |
| Maximum Overload | 30% vol. O2 |
| Sensitivity | 80 mA to 130 mA in Air |
| T50 Response Time | < 10 seconds (@ 20°C) < 15 seconds (@ -40°C to +60°C) |

|
|
YJJ 1O2 AAW85-07WA-CIT Electrochemical Oxygen O2 Gas Sensor Is Used For Industrial Safety Images |